50-2500kva / 10kv super past yo'qotadigan quruq tipirer

50-2500kva / 10kv super past yo'qotadigan quruq tipirer

SCB13

● Yuqori kuchlanish yon kuchlanishi:6KV, 6.3KV, 10 kV, 10,5 kV, 11kv

● Kam kuchlanishning past kuchlanishi:0.4kv

● Tasvir diapazoni: ±2×2.5%, ±5%

● Transformatsion vektor guruhi:Yin0 yoki DYL11

● Changity-ga teging:NLTC yoki OLTC

● Sertifikatlash:ISO9001, IEC60076 va boshqalar.

Eslatma:Xaridor talablariga muvofiq ko'proq parametrlarni sozlash mumkin.

To'lov va etkazib berish shartlari

● Minimal buyurtma miqdori:1 bo'lak

● Yetkazib berish vaqti:10 dan 20 kun

● Qadoqlash tafsilotlari:Yog'och qutisi

● To'lov shartlari:T / T, L / C, PayPal, Alipay / Wovat to'lovi, viza

Mahsulot haqida umumiy ma'lumot

 

 

Zararli energiya samaradorligini va ishonchli quvvat manbaini qidiryapsizmi? SCB13 seriyali 50-2500kva / 10 kV Quruq tipidagi elektr transformatori sizning zamonaviy quvvat tizimingiz uchun ideal tanlovdir. Energiya samaradorligi standartlariga javob beradigan ilg'or mahsulot sifatida (Gb 20052-202020 yil energiya samaradorligi) sanoat, tijorat, infratuzilma va kam yo'qotish uchun kam ta'minlanganlik va kam yo'qotishlar uchun qat'iy talablarga javob beradi.

Ishlash nuqtai nazaridan, uning yuklanishining yo'qolishi SCB11 seriyasidan 20% pastroq va yuk tashish 12% ga optimallashtiriladi. Tuzilish va texnologiya nuqtai nazaridan transformator ko'p qatlamli zich va yuqori bosimli tog'lash jarayonini va yuqori haroratli va yuqori bosimli davolash jarayonini, qisman 0,1 mm.

 

 

 

Turi va ma'nosi

 

 

1

 

 

 

Ilova doirasi

 

 

1. O'rnatish balandligi: dengiz sathidan 1000 milliondan oshmasligi;

2. Elektr tarmog'idagi kuchlanishli to'lqinlar taxminan sinusoidal;

3

4. Maksimal harorat +40} darajasi;

5. O'rta kunlik o'rtacha harorat +30} darajasi;

6. O'rtacha yillik o'rtacha +20} darajasi;

7. Minimal harorat --25 daraja (yopiq transformatorlarga nisbatan qo'llaniladi).

 

 

 

Mahsulot xususiyatlari

 

 

 

Yuqori yadroli ishlash

Quruq tsituvchi transformatorlarimiz yuqori sifatli donga asoslangan sovuq moyli silikon temir yo'llaridan foydalanadilar. Ushbu material yuqori magnitli o'tkazuvchanlikka ega va asterezning yo'qolishi va eddi hozirgi yo'qotishlarini samarali kamaytirishi mumkin. Shu bilan birga, 45 daraja to'liq egiluvchan stol taramlash jarayoni magnit zanjirni yumshoq qiladi va magnit qarshilikni kamaytiradi.

Yaxshi namlikning zararli ishlashi

Transformatorning umumiy namoyishi juda yaxshi. Shamol erishi uch bardoshli bo'yoq bilan püskürtülür bo'lishi mumkin. U hali ham 100% namlik ostida ishlashi mumkin. O'chirishdan keyin oldindan quritishsiz foydalanish mumkin. U tunnellar, er osti elektr stantsiyalari va boshqa joylar kabi nam muhitlarga moslashishi mumkin.

Ishonchli elektr ko'rsatkichlari

Ushbu quruq tigiri transformatorning yuqori voltli sinishi, o'ralgan qatlamlar orasidagi kuchlanishni kamaytiradigan segmentli va qatlamli dizaynni qabul qiladi. Shuningdek, u epoksi qatronini vakokli qatronni qabul qiladi, bu esa, burilish ichidagi qisman oqindi miqdorini kamaytiradi va palokning elektr ko'rsatkichlarini yaxshilaydi.

 

 

 

 

Asosiy texnik parametrlar

 

 

Baholash
sig'im
(KVA)

Kuchlanish kombinatsiyasi

Vektor
Guruh

Yuklamoq
yo'qotish
(W)

Yuk yo'qotish (W)

Yuklamoq
hozirgi
(%)

Urg'u
Kuchlanishi
(%)

Tovush
Daraja

(db)

Umumiy

o'lchov
(L×W×H)

Jami
vazn
(kg)

Baland
Kuchlanishi
(kV)

tegmoq
oraliq

Past
Kuchlanishi
(kV)

130 daraja (b)

155 daraja (F)

180 daraja (H)

100 daraja

120 daraja

145 daraja

30

6.3
6.6
10
10.5
11

±2×2.5
±5

0.4

Ayyorlik

135

605

640

685

0.6

4.0

57

955×1100×840

360

50

195

845

900

965

0.6

970×1120×860

420

80

265

1160

1240

1330

0.6

58

1015×1150×925

460

100

290

1330

1415

1520

0.6

1060×1210×960

560

125

340

1565

1665

1780

0.6

59

1075×1230×1000

630

160

385

1800

1915

2050

0.6

1105×1260×1045

770

200

445

2135

2275

2440

0.5

60

1120×1270×1105

875

250

515

2330

2485

2665

0.5

1195×1350×1125

1055

315

635

2945

3125

3355

0.5

62

1225×1380×1140

1190

400

705

3375

3590

3850

0.4

1315×1470×1190

1500

500

835

4130

4390

4705

0.4

63

1345×1500×1265

1700

630

965

4975

5290

5660

0.4

63

1555×1700×1175

1985

630

935

5050

5365

5760

0.3

6.0

63

1555×1700×1175

1985

800

1090

5895

6265

6715

0.3

65

1600×1750×1220

2360

1000

1275

6885

7315

7885

0.3

1660×1810×1285

2775

1250

1505

8190

8720

9335

0.25

67

1720×1870×1350

3310

1600

1765

9945

10555

11320

0.25

1780×1930×1405

3940

2000

2195

12240

13005

14005

0.2

69

1840×1990×1475

4595

2500

2590

14535

15455

16605

0.2

1900×2050×1565

5495

1600

1760

11000

11600

12500

0.25

8.0

67

1780×1930×1405

3940

2000

2190

13500

14300

15400

0.2

69

1840×1990×1475

4595

2500

2590

15900

17000

18200

0.2

1900×2050×1565

5495

 

1Biz bilan bog'lanish.

2. Turli xil kuchlanishning transformatorlari foydalanuvchi ehtiyojlariga muvofiq qisqa tumanli chaqiriqlar va ulanish rejimlarini taqdim etish mumkin.

3. Jadvaldagi og'irlik va o'lchovli ma'lumotlar faqat ma'lumot uchun mo'ljallangan va oldindan ogohlantirmasdan o'zgarishi mumkin.

 

 

 

TSS

 

 

Savol: Yetkazib berish muddati qancha?

Javob: Oddiy 10 kun ichida. Bu tafsilot uchun tafsilotlar va miqdorga bog'liq. Tafsilotlar uchun biz bilan bog'laning.

Savol: Mahsulotni kotirovka olish mumkinmi?

Javob: Siz biz bilan har qanday vaqtda veb-saytdagi aloqa ma'lumotlari orqali bog'lanishingiz mumkin. Siz bizning javobimizni 24 soat ichida olasiz.

Savol: Savdo xizmatlari nimadan zavqlanishim mumkin?

Javob: Transformator bir yillik kafolat bilan birga keladi. Uzoq muddatli onlayn-texnik yordam, mijozlar malakasini oshirish va texnik qo'llanmalar va texnik qo'llanmalar bo'yicha muntazam ravishda yangilanadi.

Savol: Transformatorning o'rtacha umri qancha davom etadi?

Javob: Harbiy 20 yildan 40 yilgacha bo'lgan, texnik xizmat ko'rsatish darajasi, foydalanish muhiti va yuklash sharoitlari kabi omillarga ta'sir ko'rsatadi.

Savol: Transformatorning parametrlarini qanday aniqlash mumkin?

Javob: Biz odatda transformator namellari, chizmalar, konturlar rasmlari va texnik jadvallardagi parametrlarni topamiz.

Savol: Sizda neftga chalingan transformatorlar va zaxirada qurigan quruq tiplovchilar bormi?

Javob: Transformatorlar talabga asoslangan moslashtirilgan parametrlarni talab qiladi, biz odatda ularni buyurtma olgandan keyin ularni yaratishingiz kerak.

 

Issiq teglar: 50-2500kva / 10kv super past yo'qotish elektr transformatori, Xitoy 50-2500kva / 10kv super past yo'qotish Quruq tipdagi ishlab chiqaruvchilar, etkazib beruvchilar, zavodlar

So'rov yuborish